Innovation Electronic Co.,Ltd
Use our Machine To Make Your Weighing and Packing Line Easier, Faster and More Cost Saving!
Product Details:
Payment & Shipping Terms:
|
| Pattern: | Single Point Load Cell | Capacity: | 100kg To 750kg |
|---|---|---|---|
| Material: | Stainless Steel | Application: | Platform Scale |
| Interchangeable Brand: | HBM | IP Protection Standard: | IP67 |
| Accuracy Grade: | C3 | Non-linearity: | 0.0166 |
| Size: | 139.7*30.5*30.2 | ||
| Highlight: | platform load cell,weighing machine using load cell |
||
− Accurasy calss C3MR with OIML R60 test Report
− Max. Capacities: 100 kg...750 kg
− Off center load compensated(OIML R76)
− Complies with EMC guidelines
-- Six-wire configuration
− 6-wire circuit
-- platform size 600x800mm
| Type | IPWSE | |||||||||
| Accuracy class1) | C3MR | |||||||||
| Number of load cell intervals (nLC) | 3000 | |||||||||
| Maximum capacity (Emax)2)) | kg | 100 | 200 | 300 | 500 | 750 | ||||
|
Minimum LC verification interval (vmin) Accuracy class C3 |
g | 10 | 20 | 20 | 50 | 50 | ||||
|
Temperature effect on zero balance (TK0) Accuracy class C3
|
% v. Cn / 10 K
|
±0.0140 | ±0.0140 | ±0.0093 | ±0.0140 | ±0.0093 | ||||
| platform size | mm | 600 x 800 | ||||||||
| Max. platform size | 800 x 800 | |||||||||
| Sensitivity (Cn) | mV/V | 2.0±0.2 | ||||||||
| Zero balance | 0±0.1 | |||||||||
|
Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] |
% v. Cn / 10 K
|
±0.0170 ±0.0117 |
||||||||
| Hysteresis error (dhy)3) | % of Cn | ±0.0166 | ||||||||
| Non-linearity (dlin)3) | ±0.0166 | |||||||||
| Minimum dead load output return (DR) | ±0.0166 | |||||||||
| Off center load error4) | ±0.01 | |||||||||
| Input resistance (RLC) | Ω | 390±15 | ||||||||
| Output resistance (R0) | 359±10 | |||||||||
| Reference excitation voltage (Uref) | V | 5 | ||||||||
| Nominal range of excitation voltage (BU) | 1...12 | |||||||||
| Max. excitation voltage | 15 | |||||||||
| Insulation resistance (Ris) at 100 VDC | GΩ | > 2 | ||||||||
| Nominal temp. range (BT) |
°C [°F] |
−10 ... +40 [+14 ... +104] | ||||||||
| Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | |||||||||
| Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | |||||||||
|
Safe load limit (EL ), at max. 100mm eccentricity |
% of Emax |
150 | ||||||||
| Lateral load limit (Elq), static |
% of Emax |
300 | ||||||||
| Breaking load (Ed) | 300 | |||||||||
| Weight (G), approx. | kg | 0.9 | 0.9 | 1.1 | 1.2 | 1.2 | ||||
|
Protection class according to EN 60 529 (IEC 529) |
IP67 | |||||||||
|
Material: Measuring element Coating Cable sheath |
Stainlesssteel 1.4545 PVC |
|||||||||
Contact Person: Miss. TINA LIU
Tel: +8618758163948
Fax: 86-571-8838-5175