Innovation Electronic Co.,Ltd
Use our Machine To Make Your Weighing and Packing Line Easier, Faster and More Cost Saving!
Product Details:
Payment & Shipping Terms:
|
Type: | Single Point Load Cell | Capacity: | 0.3kg 0.5kg 2kg 3kg |
---|---|---|---|
Output: | 2mv/v | Material: | Aluminum |
Application: | Electronic Balance | Interchangeable Brand: | HBM |
IP Protection Standard: | IP67 | Accuracy Grade: | C3 |
Hysteresis Error (dhy)3): | ±0.0150 | Non-linearity (dlin)3): | ±0.0150 |
High Light: | 500g Aluminum Single Point Load Cell,2000g Aluminum Single Point Load Cell,electronic load cell for electronic balance |
Small Size Low Capacity Load Cell Shielded Connection Cable For Electronic Balance
Good quality and long life
− For determining small masses − Small size − Accuracy class C3 with OIML- R60 test report − Off center load compensated − Degree of protection IP65 according to IEC 529 − Shielded connection cable
|
Type | IPW4MC3 | |||||||
Order-No. | 1-PW4C3/300G-1 | 1-PW4C3/500G-1 | 1-PW4C3/2KG-1 | 1-PW4C3/3KG-1 | ||||
Accuracy class1) | C3 | |||||||
Number of load cell intervals (nLC) | 3000 | |||||||
Maximum capacity (Emax)2)) | g/kg | 300 | 500 | 2 | 3 | |||
Minimum LC verification interval (vmin) | g | 0.05 | 0.1 | 0.2 | 0.5 | |||
Temperature effect on zero balance (TK0) |
% v. Cn / 10 K
|
0.0233 | 0.0280 | 0.0140 | 0.0233 | |||
Max. platform size | mm | 800 x 800 | ||||||
Sensitivity (Cn) | mV/V | 1.0±0.1 | 2.0±0.2 | |||||
Zero balance | 0±0.1 | |||||||
Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] |
% v. Cn / 10 K % of Cn |
±0.0175 ±0.0117 |
||||||
Hysteresis error (dhy)3) | ±0.0150 | |||||||
Non-linearity (dlin)3) | ±0.0150 | |||||||
Minimum dead load output return (DR) |
Ω |
±0.0245 | ||||||
Off center load error4) | ±0.0233 | |||||||
Input resistance (RLC) | 380±38 | |||||||
Output resistance (R0) | 380±38 | |||||||
Reference excitation voltage (Uref) | V | 5 | ||||||
Nominal range of excitation voltage (BU) | 15 | |||||||
Insulation resistance (Ris) at 100 VDC |
GΩ |
> 2 | ||||||
Nominal temp. range (BT) |
°C [°F] |
−10 ... +40 [+14 ... +104] | ||||||
Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | |||||||
Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | |||||||
load limit (EL ) at max. 100mm eccentricity |
% of Emax % of Emax |
150 100 |
||||||
Lateral load limit (Elq), static | 200 | |||||||
Breaking load (Ed) | >300 | |||||||
Deflection at Emax (snom), approx. |
mm kg |
< 0.4 | ||||||
Weight (G), approx. | 0.07 | |||||||
Protection class according to EN 60 529 (IEC 529) |
IP67 | |||||||
Material: Measuring element Coating Cable sheath |
Aluminum Silicone rubber PVC |
Contact Person: Miss. TINA LIU
Tel: +8618758163948
Fax: 86-571-8838-5175