Innovation Electronic Co.,Ltd
Use our Machine To Make Your Weighing and Packing Line Easier, Faster and More Cost Saving!
                    Product Details:
 Payment & Shipping Terms:
  | 
                            
| Type: | Single Point Load Cell | Capacity: | 10kg 20kg 30kg 50kg 100kg | 
|---|---|---|---|
| Output: | 2mv/v | Material: | Stainless Steel | 
| Application: | Checkweigher, Filling Scale Machine | Interchangeable Brand: | HBM PW15AH 10kg 20kg 30kg 50kg 100kg | 
| IP Protection Standard: | IP68,IP69 | Accuracy Grade: | C3 | 
| Highlight: | 10kg load cells for platform scales,20kg load cells for platform scales,platform load cell | 
			    	||
IN PW15AH 10KG 20KG 50KG 100kg single point stainless steel load cell for check weigher and filling scale machine
IN- PW15AH Single point load cell
-- STAINLESS STEEL
---IP69K
---10KG 20kg 30kg 50kg 100kg
Good quality with competitive price
| Type | PW15AH | ||||
| Accuracy class1) | C3 Multi Range (MR) | ||||
| Number of load cell intervals (nLC) | 3000 | ||||
| Maximum capacity (Emax)2)) | kg | 10 | 20 | 50 | 100 | 
| Minimum LC verification interval | g | 1 | 2 | 5 | 10 | 
| 
			 Temperature effect on zero balance  | 
			
			 % v. Cn / 10 K 
  | 
			±0.0140 | ±0.0140 | ±0.0140 | ±0.0140 | 
| Max. platform size | mm | 500 x 400 | |||
| Sensitivity (Cn) | mV/V | 2.0±0.2 | |||
| Zero balance | 0±0.1 | ||||
| 
			 Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉]  | 
			
			 % v. Cn / 10 K 
  | 
			
			 ±0.0175 ±0.0117  | 
		|||
| Hysteresis error (dhy)3) | % of Cn | ±0.0166 | |||
| Non-linearity (dlin)3) | ±0.0166 | ||||
| Minimum dead load output return (DR) | ±0.0166 | ||||
| Off center load error4) | ±0.0233 | ||||
| Input resistance (RLC) | Ω | 300 ... 500 | |||
| Output resistance (R0) | 330 ... 500 | ||||
| Reference excitation voltage (Uref) | V | 5 | |||
| Nominal range of excitation voltage (BU) | 1...12 | ||||
| Max. excitation voltage | 15 | ||||
| Insulation resistance (Ris) at 100 VDC | GΩ | > 1 | |||
| Nominal temp. range (BT) | 
			 °C [°F]  | 
			−10 ... +40 [+14 ... +104] | |||
| Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | ||||
| Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | ||||
| Safe load limit (EL ), | 
			 % of Emax  | 
			150 | |||
| at max. eccentricity | mm | 160 | |||
| Lateral load limit (Elq), static | 
			 % of Emax  | 
			300 | |||
| Breaking load (Ed) | 300 | ||||
| Deflection at Emax (snom), approx. | mm | < 0.5 | |||
| Weight (G), approx. | kg | 1.0 | |||
| 
			 Protection class according to EN 60 529 (IEC 529)  | 
			IP68(test conditions 100 h at 1m water column);IP69K(water at high presure,steam jet cleaning) | ||||
| 
			 Material: Measuring element Coating Cable sheath  | 
			
			 C1.4545 Silicone rubber PVC  | 
		||||
![]()
![]()
![]()
Contact Person: Miss. TINA LIU
Tel: +8618758163948