Send Message

Innovation Electronic Co.,Ltd

 

Use our Machine To Make Your Weighing and Packing Line Easier, Faster and More Cost Saving!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsStatic Charging Equipment

INAB706C White PFE Particle Electrostatic Charge device Filtration Efficiency Tester 2.83L/min ±5%

Customer Reviews
Fast sending, and good communication. Stuff tested, really great, thank you!

—— Pratik Rastogi

Excellent collaboration and communication. I can only recommend.

—— Alireza Green

Excellent quality! I've been looking for a high accuracy for a long time, here I find it!

—— Larry Geminiani

I'm Online Chat Now

INAB706C White PFE Particle Electrostatic Charge device Filtration Efficiency Tester 2.83L/min ±5%

Detailed Product Description
Name: Particle Filtration Efficiency Tester Model: INAB706C
High Light:

Filtration tester Static Charging Equipment

,

PFE Particle Static Charging Equipment

,

100cm2 Filtration Efficiency Tester

INAB706C

Particle filtration efficiency tester(PFE)

 

INAB706C PFE Particle 100cm² Filtration Efficiency Tester

Product overview】: 

Particle filtration efficiency tester,suitable to test the filter material efficiency of 45-99.9% grade,test the filter according to international standard.The test bench is designed to be compact, lightweight, and during the test run, only suitable power and compressed air (no water, no oil) are needed. It is suitable for use in laboratory, factory, etc.

Test philosophy】:

The test sample is fixed on the fixture, and the test air volume corresponds to the required filtration speed.The aerosol produced by the aerosol generator is adjusted, then electrostatic neutralization (PSL), and then mixed with the filtered test air evenly, and then entered the test area through the filter material.In addition, it is necessary to measure the resistance of the filter material during the test and manually adjust the control flow.The product conforms to jjf1190-2008.

Reference standard】:

GB/T 32610-2016 Technical specifications for daily protective masks

GB 2626-2006 Respirator - self - imbibition filter respirator against particulate matter

 

GB 19082-2009 Technical requirements for disposable protective clothing for medical use
GB 19083-2010 Technical requirements for medical protective masks
YY 0969-2013 Disposable surgical mask

 

YY 0469-2011 Medical surgical masks

ISO-29463 Use hepa filters and filtration media to remove particulate matter from the air

Particle filtration efficiency tester【Constituent part】:

1. Aerosol generator

It is mainly used for the test of high concentration aerosol,PSL standard particles of 0.3um are used, and the particle size range of the main particles emitted is ≥0.3um, accounting for more than 70% of the total, which can continuously and stably produce aerosols. Upstream of the filter material, the test particles are provided.

2. Particle counter

It is mainly used to monitor the concentration of upstream and downstream particles of the measured filter material and obtain the efficiency of the measured filter material.

3.Differential pressure transducer

It is mainly used to test the pressure difference (or resistance) of the measured filter material under a certain test flow rate.

4.Stainless Steel Clamps

Mainly used for the pressure and sealing of the measured filter material.

5.Air pump

Mainly used for the test flow through the filter material, stable flow, green energy saving, small vibration noise.

6.Electrical control and software

Circuit control and operation of equipment, calculation and data processing of software, stability judgment of upstream concentration, operation control, parameter setting.

 

 

 

Particle filtration efficiency tester【Functional description】:

A. Filtration efficiency test and airflow resistance:

1. The whole test equipment adopts negative pressure system.

2. Air and aerosols enter through the test chamber and flow through the mask according to the standard

3. Two particle counters are used to detect the concentration of upstream and downstream and calculate the filtration efficiency. The pressure difference between upper and lower parts of the mask was detected by the pressure difference meter.

4. The rated flow rate is achieved by pumping.

5. Produce standard aerosol materials by aerosol generator.

6. Through the PLC and the display screen to carry out the operation of the equipment and the efficiency of the calculation of resistance.

 

 

 

 

 

 

 

 

 

 

 

 

Technical parameters】:

 

Test efficiency range 45%-99.9%@≥ 0.3μ m
Test area 100cm²
Test differential pressure range 0-50pa± 1% , 50-500pa± 1.5%
Test flow of measured filter material 25-100L/min±2.5%(adjustable)
Test aerosol types PSL
Counter sampling flow 2.83L/min ±5%
Particle size display @≥0.3um
Counter laser source Laser diode
Air pump Continuous working stability
Data memory capacity 1∽ 1000 sets of measurement data, can be exported
Screen display Color 7-inch touch screen
Printing method Built-in thermal printer
Power supply AC 220V/50Hz
Power 1kw
Data export interface USB

 

Environment

Operating environment: 0∽ 40℃ Relative humidity: 10∽ 70%
Storage environment: 0℃∽ 45℃Relative humidity: 0∽ 70%

 

Standard accessories

Thermosensitive printing paper, hose (Outer diameter 6mm and 15mm), operating instruction, test report, qualification certificate
Overall dimensions L 1000X W 760X H 1750(mm)
Material Shell steel coating, test unit SUS304 stainless steel
weight 150Kg
Accessories:
PSL Aerosol generator
Electrostatic neutralizer
Diluter

 

 

 

 

Contact Details
Innovation Electronic Co.,Ltd

Contact Person: Miss. TINA LIU

Tel: +8618758163948

Fax: 86-571-8838-5175

Send your inquiry directly to us (0 / 3000)