Product Details:
Payment & Shipping Terms:
|
Pattern: | Canister Column Compression Load Cell | Capacity: | 5T, 10T, 20T, 30T |
---|---|---|---|
Output: | 2mv/v | Material: | Stainless Steel/Alloy Steel |
Application: | Truck Scale | Interchangeable Brand: | HBM, RICELAKE RC3 |
7.IP Protection Standard: | IP68 | Accuracy Grade: | OIML C2 C3 |
Cable Length: | 8m | Size: | 5t:diameter:85mm Height:180mm |
Item | Unit | Parameter | |
Accuracy class to OIML R60 | C2 | C3 | |
Rated capacity (Emax) | 5,10,20 ,30 | ||
Minimum LC verification interval (Vmin) | %ofEmax | 0.0200 | 0.0100 |
Sensitivity (Cn) I Zero balance | mV/V | 2.0±0.002 I 0± 0.02 | |
Temperature effect on zero balance (TKo) | % ofCn/10K | ± 0.02 | ± 0.0170 |
Temperature effect on sensitivity (TKc) |
% ofCn/10K |
± 0.02 | ± 0.0170 |
Hysteresis error (dhy) | %ofCn | ± 0.0270 | ± 0.0180 |
Non-linearity(dlin) | %ofCn | ± 0.0250 | ± 0.0167 |
Creep(dcr) over 30 min. | %ofCn | ± 0.030 | ± 0.0167 |
Input (RLC) &Output resistance (Ro) |
Ώ |
IN-RC3:400±10&352±3 IN-RC3Y:700 ±20 &706±7 |
|
Nominal range of excitation voltage (Bu) | V | 5---15 | |
Insulation resistance (Ris) at 50Vdc | MQ | ≧5000 | |
Service temperature range (Btu) | ℃ | -30...+70 | |
Safe load limit (EL) & Breaking 10ad(Ed) | %ofEmax | 150 &250 | |
Protection class according to EN 60 529 (IEC 529) | IP68 | ||
Material :Measuring element+housing | Stainless or alloy steel +Stainless steel |
Maximum capacity(Emax) | 5t | 10t | 20t | 30t | |
Min. scale verification (emin) according to EN45501 [...#=max.Number of load cells] |
kg |
2 [4#] |
5 [6#] |
5 [6#] |
10 [10#] |
Deflection at Emax (snom) ,approx | mm | 0.55 | 0.55 | 0.65 | 0.75 |
Weight(G) ,approx | kg | 1.8 | 1.9 | 2.1 | 2.3 |
Cable : Diameter: Ø 6mm Length | m | 8 | 10 | 12 |
15 |
Contact Person: Zeng